If after checking all the above points, the refrigerator is
still not working satisfactorily, contact your nearest
service engineer. State the problem, model, product-
and serial-number.
(Details of the model, product- and serialnumber are
to be found on the data label in the top left of the
inside compartment.)
Refrigerators until serial number 634xxxxx are
equipped with overheating protection on the cooling
unit. An authorised service technician can check
whether this has been triggered or not.
Refrigerators from serial number 634xxxxx, instead of
having overheating protection, are equipped with a
second (evaporator) sensor.
In the event of a fault developing, contact your nearest
Service Centre-see local telephone directory.
13. Putting into operation
Technical data:
13.1 Connecting to electrical mains
The appliance may only be operated from
nominal voltage mains as shown on the data
plate. The appliance mains plug may be connected to
a mains socket earthed in accordance with
regulations.
Any electrical work required to install this appliance
should be carried out by a qualified electrician or
competent person.
The manufacturer declines any liability should
these safety measures not be observed.
Electrical Requirements
Before switching on, make sure the electricity supply
voltage is the same as that indicated on the appliance
rating plate.
Model RH 131LD, RH 131D RH 141LD, RH 141D
Type MF20-60 MF20-60
Gross volume 31 litres 41 litres
Mains operation 120V (AC) 120V (AC)
Input 90W 90W
Energy consumption 0,9 kWh/24h 0,98 kWh/24h
Climate class N N
Refrigerant 159g H
2
O + 86g NH
3
159g H
2
O + 86g NH
3
14. Environmental
protection information
The appliance does not contain any CFCs/HCFCs.
Ammonia (natural hydrogen and nitrogen
compound) is used as a refrigerating agent in the
refrigeration unit.
The ozone-friendly cyclopentane is activated as a
motive agent for the PU foam insulation.
Sodium chromate is used for corrosion protection
(less than 2 weight % of the coolant).
15. Recycling
After unpacking the appliance, the packing
materials should be delivered to a local collection
site. At the end of its useful lifetime, the appliance
should be delivered to a specialized collection and
reprocessing firm, which reclaims the usable
materials. The rest is properly destroyed.
This appliance complies with the following
directives:
ANSI/UL STD: 250
CAN/CSA - C22.2 No. 63 - 93
Printed by Océ Hungária Kft. 2006. 10. 05.