400 70 69-00, Rev.2 DOMETIC ABINSTRUCTION FOR INSTALLATIONTRAVEL POWER®230 V AC, 16 A (991 00 10-06)CONTENTS Page1. GENERAL INFORMATION 32. BEFORE INS
10Check the choice of pulleys according to the following instructions:- Find out the maximum rpm for the engine (Max).- Find out the engine's rpm
113. INSTALLATIONInstallation of Travel Power must be made by an authorized Travel Powerworkshop. See section 7, Figure 11, for wiring diagram.Before
123.2 INSTALLATION OF THE POWER BOXWARNING! HIGH VOLTAGE! The cover of the power box must not beremoved at any time. To cut, drill into, or in any oth
13Note to locate the Power box in horizontal position leads to higher risk forliquid to trickle through the air inlet. Be therefore observant when to
143.3 INSTALLATION OF THE SHIELDED CABLEPlease observe! The output voltage from the Travel Power generatoris considerably higher than the output from
15The cable is to be mounted in the sockets on the generator as shown inFigure 7. Each cable conductor is marked with a number between 1 and 5.These s
163.4 ON-OFF SWITCHThe on-off switch is delivered as standard in the cover of Travel Powerbox. If another location of the on-off switch is requested p
17Figure 9. On-off switchFigure 8
183.5 INSTALLATION OF 230 V ACAn authorized installer must do the 230 V AC installationConnection to the 230 V is made on the socket shown in Figure 1
194. CHECKLIST BEFORE USEDo not turn on the ignition and do not use Travel Power before athorough check of the installation has been made!4.1 Mechanic
ENGLISHInstructions for installationNOTE Travel Power is not intended for powering life supportsystems.The instruction for installation is intended fo
205. TECHNICAL DATA991 00 10-06 TRAVEL POWER 230 V AC, 16 APower boxOutput voltage 230 V ±5 % (RMS)Output power continuously 3500 W (Resistive loa
21Figure 11. Detailed dimensions of the Power box
226. FAULT TRACING6.1 SCHEME FOR FAULT TRACINGUse caution when fault tracing on Travel Power. Please observe thatthis is a 230 V installation.Is there
236.2 TRACING SCHEME WHEN RED LAMP LITUse caution when fault tracing on Travel Power. Please observe thatthis is a 230 V installation.Red LED is lit Y
246.3 FAULT TRACING BEFORE CONTACTING THE RETAILER To prepare before contacting the Travel Power representative the pointsbelow should be worked throu
255. If none of the above points gives any indication on faults it may be possible thatthe generator has been demagnetised. To check this follow the
267. WIRING DIAGRAM FOR TRAVEL POWER, 230 V, 16 ATo be used with Travel Power 991 00 10-06Figure 11. Wiring diagramTravel PowergeneratorA: Switch devi
27DOMETIC AB ENERGY SYSTEMS SE-171 54 SOLNA SWEDENPh: + 46 (0)8 501 025 00 Telefax: +46 (0)8 501 025 98/99
31 GENERAL INFORMATION1.1 SAFETY PRECAUTIONSThe output voltage from the Travel Power generator is considerably higherthan the output voltage from a re
42 BEFORE INSTALLATIONMake sure that the product is complete and undamaged.PLEASE OBSERVE! In the event of damage caused by transportation, thebuyer m
52.3 IF NO CUSTOM-MADE INSTALLATION KIT IS AVAILABLE,FOLLOW THESE INSTRUCTIONSFor a complete mounting kit, brackets, pulleys and other parts have to b
6PLEASE OBSERVE !It is of greatest importance that thegenerator pulley is mounted inparallel to and aligned with thecrankshaft pulley as shown in Figu
8To obtain as good alignment as possible between the drive pulley and thegenerator pulley it can be necessary to put washers on the generator shaft be
92.4 PULLEY DIAMETER DESIGNTabulated below is the approximate generator rpm corresponding to theavailable power:3000 rpm - 1000 W3600 rpm - 1800 W5500