ELECTRICAL CONNECTION
120 V AC CONNECTION
The refrigerator is equipped with a three-prong (grounding)
plug for your protection against shock hazards and should be
plugged directly into a properly grounded threeprong recep-
tacle. Do not cut or remove the grounding prong from this
plug.
The free length of the cord is 2 feet and
it is recommended that the receptacle is
located to the left of the refrigerator
(viewed from the rear) and approx. 6
inches from the oor. This allows easy
access through the vent door. The cord
should be routed to avoid direct contact
with the burner cover, ue cover or any
other components that could damage the
cord insulation.
12 V DC CONNECTION (RM2510)
12 V DC must be connected to the refrigerator to provide
power for operation of the automatic reigniter. The connection
is made to the terminal block marked 12 V, located on the back
of the refrigerator cabinet. Correct polarity must be observed
when connecting to the DC supply. The refrigerator must be
connected to the battery circuit with a maximum fuse size of 3
amps and a minimum wire size of 14 gauge.
NOTE!
Do not use the chassis or vehicle frame as one of the
conductors. Connect two wires at the refrigerator and route to
the DC supply.
120 Volt AC
receptacle
6”
INSTALLATION INSTRUCTIONS
TESTING LP GAS SAFETY SHUTOFF
The gas safety shutoff must be tested after the refrigerator is
connected to the LP gas supply.
RM2410
To test the gas safety shutoff, proceed as follows:
Turn on the refrigerator.
Check that the gas ame is lit. This can be observed
through the reector (E).
Close the gas valve by turning the knob (A) back to
the OFF position.
Wait one (1) minute.
Remove the protection cover.
Open the gas valve by turning the knob (A) to posi-
tion GAS without pushing the buttons (C) and (D).
Apply a non-corrosive commercial bubble solution
to the burner jet. Be careful not to damage the burner
jet.
No bubbles should appear at the opening of the
burner jet. Bubbles indicate a defective gas safety
shutoff and service is required.
If no bubbles were present at the burner jet, rinse the
orice with fresh water. Be careful not to damage the
burner jet orice.
Replace the protection cover.
Turn on the refrigerator. Normal gas operation
should return. Allow the burner to operate for a mini-
mum of 5 minutes.
RM2510
To test the gas safety shutoff, proceed as follows:
Turn on the refrigerator.
Check that the gas ame is lit and the lamp (E) is
out.
Close the gas valve by turning the knob (A) back to
the OFF position.
Wait one (1) minute.
Disconnect the 12 V DC power.
Remove the protection cover.
Open the gas valve by turning the knob (A) to posi-
tion GAS without pushing button (C). The reigniter
should not be sparking.
Apply a non-corrosive commercial bubble solution
to the burner jet. Be careful not to damage the burner
jet.
No bubbles should appear at the opening of the
burner jet. Bubbles indicate a defective gas safety
shutoff and service is required.
If no bubbles were present at the burner jet, rinse the
orice with fresh water. Be careful not to damage the
burner jet orice.
Replace the protection cover.
Reconnect the 12 V DC power to the refrigerator.
Turn on the refrigerator. Normal gas operation
should now return. Allow the burner to operate for a
minimum of 5 minutes.